Development Information
Completeness Checklist by Discipline
Environmental
- Variances
- E/S control and Tree Protection Plans
- Slope Map, Grading & Appendix Q-1 & Q-2
- CEF's, Environmental assessment and Engineer's Report.
- Plat Notes.
- Landscape Plans; Appendix C, notes & Standard Details.
- CWQZ, WQTZ & 100 Year Floodplain.
- Appendix T.
- Watershed Status and Standard notes.
- 1704 Determination and restrictive covenant.
Subdivision
- Zoning
- Proof of Ownership
- Tax Certificates
- Indicating no taxes owed
- Covering property in it's entirety (total acreage)
- Tax Plats Current (if notification is applicable)
- Previous Recorded Plat (if proposing amended plat or resubdivision)
- Is preliminary plan necessary?
- Verify Jurisdiction
- If final w/prelim - make sure they match
- Scale of plat
- Utility providers
- Copies of deeds
- Whether in Neighborhood plan or not
- If small lot subdivision, ask for draft or final version of Small Lot Document (R.C.)
- If any R.C.'s referenced in submittal, then ask for copies (if not already provided)
- Check preamble for correct wording.
- If subject to parkland, note to applicant that they will need to comply.
- If site already developed, ask for As-Built Survey OR note to applicant that any approved site plan will need to be corrected/revised to match new lot configuration.
- If in correct application (amended/resub/final...etc.)
Water Quality and Drainage Construction
Preliminary Plans and Final Plats
- Engineer’s seal (w/o qualifiers), signature & date on all unbound sheets & front page of bound documents containing engineering work
- Surveyor's seal, signature & date (Final Plats only)
- Engineer's project summary letter (signed, sealed and dated by P.E.)
- Discussion of compliance with 2-year peak flow control and water quality requirements
- Provision (or formal request to Watershed Engineering Division for RSMP or waiver) for flood control compliance
- Standard notes from application packet (especially floodplain)
- Public roadways - layout, classification and geometric data
- Floodplain delineations and drainage easements (or ROW) for fully developed condition flows
- Drainage area map (off-site and on-site) with flow patterns (Preliminaries only)
- Drainage/2-year peak flow control/water quality study with hydrologic & hydraulic data for associated infrastructure
- Depiction of drainage/2-year peak flow control/water quality controls (Preliminary Plans and Finals w/o Preliminary Plans only)
- Access, operation and maintenance easements for flood, 2-year peak flow control and water quality controls
Floodplain checklist
- Floodplain note on the cover page with correct FEMA FIRM Panel number and revision letter (suffix), as well as correct effective date
- Lowest Finished Floor Elevation (FFE) on all proposed structures in relation to Mean Sea Level (MSL) (regardless of whether or not proposed structure is in the floodplain) (see Building Criteria Manual Ch. 58, Art. 8, C. 1. A.)
- Fully developed 100-year floodplain is clearly delineated
- Drainage easement wide enough to contain the fully developed 100-year floodplain delineated above, along with note indicating Drainage Easement Document Number (see Drainage Criteria Manual 25-7-152)
- No development proposed in the drainage easement
- Do the topographic lines indicate a defined channel on or near the site? If so, have they dedicated an easement (with easement document note) for this channel if the drainage area is less than 64 acres? If the drainage study is greater than 64 acres, have they provided a floodplain study?
I
- f there’s parking in the fully developed 100-year floodplain, is the average depth less than eight inches and the greatest depth no more than twelve inches? (see DCM 25-7-95)
- No development in the fully developed 25-year floodplain (see DCM 25-7-92)
- If the site plan proposes development in the central business district (CBD), the proposed structure must be at least 2 feet above the 100-year floodplain (see DCM 25-7-94). Outside the CBD, the proposed structure must be at least 1 foot above the fully developed 100-year floodplain (see BCM Ch. 58).
Site Plans/Subdivision Construction Plans
- Engineer’s seal (w/o qualifiers), signature & date on all unbound sheets & front page of bound documents containing engineering work
- Recorded Final Plat (or concurrent submittal) or legal tract determination (subdivisions only; site planner checks site plans)
- Engineer's project summary letter (signed, sealed and dated by P.E.)
- Discussion of compliance with 2-year peak flow control and water quality requirements
- Provision (or formal request to Watershed Engineering Division for RSMP or waiver) for flood control compliance
- Standard details from application packet
- Private and public roadways - layout and geometric data
- Floodplain delineations and drainage easements (or ROW) for fully developed condition flows
- Drainage area map (off-site and on-site) with flow patterns
- Drainage/2-year peak flow control/water quality study with hydrologic & hydraulic data for associated infrastructure
- Detailed drainage/2-year peak flow control/ water quality plan and physical data (existing and proposed) for associated infrastructure
- Access, operation and maintenance easements for flood, 2-year peak flow control and water quality controls
- Drainage layout map with drainage system layout
- Street and drainage plans with station and elevation
- Street and drainage profiles with support data
- Detention pond and standard details
Transportation
Preliminary Plan
- Street Design table: ROW, pavement, & cross-section for each street
- Sidewalk locations by dotted line, deferral note, or variance request
- Sidewalk note
- Survey ties across all existing streets
Final Plat with Preliminary
- Final must match preliminary
- Note that all streets constructed to COA standards
- Sidewalk locations by dotted line, deferral note, or variance request
- Sidewalk note
- Survey ties across all existing streets
Final Plat without Preliminary
- Sidewalk locations by dotted line, deferral note, or variance request
- Sidewalk note
- Survey ties across all existing streets
Consolidated Site Plan
- Driveway spacing:
- adjacent driveways within 200 ft.
- offsets from opposing driveways (undivided streets only)
- Parking table:
- proposed use and sq. ft.
- # of required and provided parking spaces
- Parking spaces:
- width, depth, and angle of stalls
- aisle width
- Accessible routes and ramps
- Existing right-of-way width
- TXDOT station numbers (if access is proposed to State highway)
- Sidewalks, deferral note, or waiver request (except on certain State highways where sidewalks are not required).
- TIA determination form
Site Plan
Consolidated Site Plan
- Correct type of application for proposed project
- Commission approval required (CUP, HCR, East Austin Overlay)
- Zoning application needed (check conditional overlay)
- Legal description, and Land Status Report if applicable
- Legal description on plan matches tax certificate (unless tax exempt)
- Boundary lines with bearings and dimensions
- All zoning districts on or near the site
- Existing land uses on adjoining tracts (& across street if compatibility)
- Site table indicating:
- total area of site
- FAR for each zoning district (except MF-1, MF-2, and MF-6)
- impervious cover for each zoning district (sq. ft. and %)
- building coverage for each zoning district (sq. ft. and %)
- Building table indicating:
- proposed use and sq. ft. for each use
- number of stories
- actual height
- total square footage for building
- Hill Country Roadway (if applicable):
- slope map
- table showing floor area & FAR by slope category (exc. SW Pkwy)
- Compatibility elevations and cross-sections (if applicable)
- Demolitions referred to Historic Preservation Officer
- Airport Hazard Area
- Small project?
- Correct tax plats (not required for small projects) - current & to scale
- Distribution: TXDOT, WWW, WT, AV, TPSD, FIRE, County, other
Construction Site Plan
- Correct type of application for proposed project
- Zoning application needed (in city limits only – check condit. overlay)
- Legal description, and Land Status Report if applicable
- Legal description on plan matches tax certificate (unless tax exempt)
- Boundary lines with bearings and dimensions
- Demolitions referred to Historic Preservation Officer (in city limits)
- Airport Hazard Area
- Small project?
- Correct tax plats (not required for small projects) - current & to scale
- Distribution: TXDOT, WWW, WT, AV, TPSD, FIRE, County, other
Revision
- Qualifies as revision
- Site and building tables updated
- Plan is still alive
- Redlined copy and new plan provided
- Zoning application needed (in city limits only – check condit. overlay)
- Distribution: TXDOT, WWW, WT, AV, TPSD, FIRE, County, other
DISCLAIMER:
Due to the variety of applications and regulations being addressed during the completeness check review process, additional information may be required depending on the specifics of each application
|